Re: mlx5_core - device's health compromised

$
0
0

Dear Erez,

 

thank you for your reply.

Attached you can find the full dmesg output of the event.

 

The temperature read by your suggested command is 51°C:

 

#mget_temp -d /dev/mst/mt4113_pciconf0

>51

 

Where is the temperature sensor actually placed in the connect-IB?

Does it measure the air temperature or the temperature of the processor?

The manual says safe range is 0-55°C, although I think this refers to room conditions.

 

Regards.